An air-source heat pump can provide efficient heating and cooling for your home, especially if you live in a warm climate. When properly installed, an air-source heat pump can deliver one-and-a-half to three times more heat energy to a home than the electrical energy it consumes. This is possible because a heat pump moves heat rather than converting it from a fuel like combustion heating systems do.
Although air-source heat pumps can be used in nearly all parts of the United States, they do not generally perform well during extended periods of sub-freezing temperatures. In regions with sub-freezing winter temperatures, it may not be cost-effective to meet all your heating needs with a standard air-source heat pump.
Systems with gas heating as a backup can overcome this problem, however. Heat pumps specifically designed for cold climates also show promise, and reverse cycle chillers may operate efficiently at below-freezing temperatures.
HOW THEY WORK
A heat pump's refrigeration system consists of a compressor and two coils made of copper tubing (one indoors and one outside), which are surrounded by aluminum fins to aid heat transfer. In heating mode, liquid refrigerant in the outside coils extracts heat from the air and evaporates into a gas. The indoor coils release heat from the refrigerant as it condenses back into a liquid. A reversing valve, near the compressor, can change the direction of the refrigerant flow for cooling as well as for defrosting the outdoor coils in winter.
When outdoor temperatures fall below 40°F, a less-efficient panel of electric resistance coils, similar to those in your toaster, kicks in to provide indoor heating. This is why air-source heat pumps aren't always very efficient for heating in areas with cold winters. Some units now have gas-fired backup furnaces instead of electric resistance coils, allowing them to operate more efficiently.
The efficiency and performance of today's air-source heat pumps is one-and-a-half to two times greater than those available 30 years ago as a result of technical advances such as:
Most central heat pumps are split-systems -- that is, they have one coil indoors and one outdoors. Supply and return ducts connect to a central fan, which is located indoors.
Some heat pumps are packaged systems. These usually have both coils and the fan outdoors. Heated or cooled air is delivered to the interior from ductwork that passes through a wall or roof.
SELECTING A HEAT PUMP
Every residential heat pump sold in this country has an EnergyGuide label, which displays the heat pump's heating and cooling efficiency performance rating, comparing it to other available makes and models.
Heating efficiency for air-source electric heat pumps is indicated by the heating season performance factor (HSPF), which is the total space heating required during the heating season, expressed in Btu, divided by the total electrical energy consumed by the heat pump system during the same season, expressed in watt-hours.
Cooling efficiency is indicated by the seasonal energy efficiency ratio (SEER), which is the total heat removed from the conditioned space during the annual cooling season, expressed in Btu, divided by the total electrical energy consumed by the heat pump during the same season, expressed in watt-hours.
The HSPF rates both the efficiency of the compressor and the electric-resistance elements. The most efficient heat pumps have an HSPF of between 8 and 10.
The SEER rates a heat pump's cooling efficiency. In general, the higher the SEER, the higher the cost. However, the energy savings can return the higher initial investment several times during the heat pump's life. A new central heat pump (SEER=12) replacing a 1970s vintage unit (SEER=6) will use half the energy to provide the same amount of cooling, cutting air-conditioning costs in half. The most efficient heat pumps have SEERs of between 14 and 18.
To choose an air-source electric heat pump, look for the ENERGY STAR® label. To qualify for the label, units must have SEERs of 12 or greater and HSPFs of 7 or greater. For units with comparable HSPF ratings, check their steady-state rating at -8.3 degrees C, the low temperature setting. The unit with the higher rating will be more efficient. In warmer climates, SEER is more important than HSPF. In colder climates, focus on getting the highest HSPF feasible.
These are some other factors to consider when choosing and installing air-source heat pumps:
PERFORMANCE ISSUES WITH HEAT PUMPS
Heat pumps can have problems with low airflow, leaky ducts, and incorrect refrigerant charge. There should be about 400 to 500 cubic feet per minute (cfm) airflow for each ton of the heat pump's air-conditioning capacity. Efficiency and performance deteriorate if airflow is much less than 350 cfm per ton. Technicians can increase the airflow by cleaning the evaporator coil or increasing the fan speed, but often some modification of the ductwork is needed.
Refrigeration systems should be leak-checked at installation and during each service call. Room heat pumps and packaged heat pumps are charged with refrigerant at the factory, and are seldom incorrectly charged. Split-system heat pumps, on the other hand, are charged in the field, which can sometimes result in either too much or too little refrigerant. Split-system heat pumps that have the correct refrigerant charge and airflow usually perform very close to manufacturer's listed SEER and HSPF. Too much or too little refrigerant, however, reduces heat-pump performance and efficiency.
For satisfactory performance and efficiency, a split-system heat pump should be within a few ounces of the correct charge, specified by the manufacturer. The technician must measure airflow prior to checking refrigerant charge because the refrigerant measurements aren't accurate unless airflow is correct. When the charge is correct, specific refrigerant temperatures and pressures listed by the manufacturer will match temperatures and pressures measured by your service technician. Verify these measurements with the technician. If the manufacturer's temperatures and pressures don't match the measured ones, refrigerant should be added or withdrawn, according to standards specified by the EPA.
ADVANCED TECHNOLOGIES: REVERSE CYCLE CHILLERS
One of the more notable innovations in air-source heat pumps is called a reverse cycle chiller (RCC). It offers the advantages of allowing the homeowner to choose from a wide variety of heating and cooling distribution systems, from radiant floor systems to forced air systems with multiple zones. It also offers the potential for lower winter electric bills and hotter air out of the supply vents for greater comfort.
An RCC is especially economical for all-electric homes or in areas where natural gas is not available. Depending on other fuel rates, it may even be the least expensive heating option among the remaining heating fuel choices.
The system consists of a standard 12 SEER, single speed, air-source heat pump, sized to the heating load rather than the usual smaller summer cooling load. The heat pump is connected to a large, heavily insulated tank of water that the heat pump heats or cools, depending on the season of the year. Most systems will use a fan coil with ducts, using the stored water to heat or cool the air and distribute it to the house.
The RCC system allows the heat pump to operate at peak efficiency even at low temperatures. This provides greater comfort and economy without the need for electric resistance auxiliary heating coils.
The RCC can also be equipped with a refrigeration heat reclaimer, which is similar to the common desuperheater coil found on the high-end heat pumps and air conditioners. The combined system costs about 25% more than a standard heat pump of similar size, and the simple payback on the additional cost in areas where natural gas is not available is about 2 to 3 years.
ADVANCED TECHNOLOGIES: COLD CLIMATE HEAT PUMP
One company has developed the cold climate heat pump, which features a two-speed, two-cylinder compressor for efficient operation, a back-up booster compressor that allows the system to operate efficiently down to 15°F, and a plate heat exchanger called an "economizer" that further extends the performance of the heat pump to well below 0°F. The system has been tested favorably by several utilities and may soon be available to consumers.
ADVANCED TECHNOLOGIES: ALL-CLIMATE HEAT PUMP
Another promising technology is an All Climate Heat Pump, which the manufacturer says can operate in the coldest days of winter without supplemental heat, maintaining comfortable indoor temperatures even when the temperature outdoors falls below zero. The heat pump could reduce heating and cooling costs 25% to 60%.
While the design of most heat pumps puts the focus on cooling, the All Climate Heat Pump was designed with heating as the primary focus. Initial costs for the All Climate Heat Pump are high, but if it continues to work as well as predicted, the energy savings over the life of the system would more than compensate for the up-front cost.
DOE - U.S. Department of Energy